vertical closed loop system
TCS Installations offer a complete turnkey package from modeling the
design of the vertical bore hole, through to the supply and installation
of the complete system up to and including the Heat Pump and then
the final commissioning and after sales management for vertical closed
loop ground source heat pump systems
Starting with client consultations and project feasibility reviews TCS
Installations can model a geothermal concept to a fully functional installed
system with design and build guarantees.

tcs group vertical closed loop


Summary of Technologies

A vertical closed loop ground source geothermal system consists of an array
of vertical pipes inserted into the ground to depths of up to 200m.The final
depth of the loop being dependant upon the geology of the ground, the thermo conductivity levels of the soil, the heat and rejection absorbtion requirements, and finally the building load profile for the building.

The ground source pipe work system carries water from ground (the heat collector rejector) to a high efficency ground source heat pump to provide the building with either hot water for the heating systems or domestic hot water
for washing purposes, and then chilled water for cooling.

The heat pump takes the energy that has stored from the ground via the ground loops and provide hot water to the building. The heat pump can then be switched into “reverse cycle” mode and will then reject heat energy into the ground loops so as to provide cooling to the building during the summer months.

TCS Installations
  • TCSi offer non fee early evaluations by project so as to provide
    key information to clients such as geological information, borefield
    sizes and costs of vertical systems
  • Assistance with C02 and energy assessment for planning
  • Provide Thermal conductivity testing to evaluate ground conditions
    prior to finalizing the overall system design
  • Confirmation of specification of system requirements and fully
    detailed modeled designs
  • Drilling of the vertical bore holes and installation of the geothermal looping
  • Installation of all external geothermal pipe work so as to connect the bore field to the internal systems
  • Supply and installation of the ground source heat pump hydraulic circuit including Valved Header Arrangements Heat Pumps, Geo Circulation Pumps, Pressurisation Sets, Dosing Systems, Expansion Vessels etc
  • Final testing of the complete geothermal circuit
  • Filling, dosing and verifying water system quality
  • Final commissioning of the system for client use
  • Provide dedicated as installed IOMs
  • Ensure the client and his representatives are trained in the
    operation of the system and equipment
Key Benefits
  • Design for Building loads from 10kw to 5000kw
  • Highest possible energy efficiency
  • Highly flexible system solution as
    modular design
  • Suitable for a high percentage of projects
    in the UK and abroad
  • Extremely low maintenance
  • Efficiency of system can be guaranteed all year round as underground is constant compared to air cooled systems that have variable ambient temperatures
  • Low Payback periods as highly efficient
    and low running/maintaince costs
  • No Fumes, No Fuel Stores, No Flues
  • No building structural requirements (or structural costs) to support geothermal systems as all installed below ground and no requirement for large internal plant spaces or roof plant areas
  • System has no visible, or noise impact
    as installed below ground therefore no
    line of sight or acoustic screens and planning becomes simplified
  • 50 years PLUS lifecycle
  • Systems are allowable under the
    Enhanced Capitol Allowance Scheme
  • Closed loop systems do not have the Environmental Agency regulatory controls
    as Open Loop systems do and due to this the closed loop systems are generally faster
    in both design and installation
vertical closed loop image 5 vertical closed loop image 6
vertical closed loop image 7
System Options
  • Simultaneous Heating and Cooling Available
  • Water to Water Heat Pump Solutions
  • Water to Direct Expansion (VRF) Solutions
  • Heat recovery
  • Free cooling
  • Single or Double Looping Systems
  • Loop depths to 200 meters so as
    to limit foot print of bore field
  • Domestic hot water supply
  • Solar water pre heating

TCS Installations Cover

TCS Installations are ISO9001: 2000 Quality systems approved

TCS Installations Provide £5m PI design professional indemnity insurance

TCS Installations are an approved member of The Safe Contractors Association

TCS Installations are a member of the International Ground Source Heat Pump

TCS Installations are an independent design & installation company that
strives to engineer the best energy efficient solution for a client and
therefore can offer a wide range of heat pump products that suit the project.